Sign In | Join Free | My udpf.com
China Tianjin Shiny-Metals Technology Co., Ltd. logo
Tianjin Shiny-Metals Technology Co., Ltd.
Shiny-Control Technology Develop (Beijing) Co., Ltd.
Verified Supplier

1 Years

Home > Wilo Recirculating Pump >

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System

Tianjin Shiny-Metals Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System

  • 1
  • 2
  • 3

Brand Name : Wilo

Model Number : Wilo-CronoTwin-DL-E

MOQ : 1

Price : discussible

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : Peak Season Lead Time, 1-3 months, Off Season Lead Time, one month

Delivery Time : 5-8 weeks

Packaging Details : Wooden case packing

Permissible temperature range : of -20 °C to +140 °C

Protection class : IP55

Nominal diameter : DN 40 to DN 200

Max. operating pressure : 16 bar up to +120 °C, 13 bar up to +140 °C

maximum flow : 375 Q/m³/h

Maximum head : 60h/m

Contact Now

Wilo CronoTwin-DL-E Recirculating Pump Electronically Controlled Twin-Head Pump For Heating Chilled Water And Cooling System

Design

Electronically controlled glanded twin-head pump in in-line design with flange connection and automatic power adjustment

Application

Pumping of heating water (acc. to VDI 2035), chilled water and water/glycol mixtures without abrasive substances in heating, chilled water and cooling systems.

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System

Equipment/function

Operating modes

  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID control
  • Constant speed (n=constant)

Manual operation level

  • Green button and display

Manual functions

  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement

External control functions

  • "Overriding Off" control input
  • “External pump cycling” control input (effective only in dual pump operation)
  • Analogue input 0 – 10 V, 0 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 – 10 V, 4 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 – 10 V for actual value signal from pressure sensor
  • Analogue input 2 – 10 V, 0 – 20 mA, 4 – 20 mA for actual value signal from pressure sensor

Signal and display functions

  • Collective fault signal SSM
  • Collective run signal SBM

Data exchange

  • Infrared interface for wireless data exchange with IR-Monitor/IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation

Safety functions

  • Full motor protection with integrated trip electronics
  • Access disable

Dual pump management (double pump or 2 x single pumps)

  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)

Typekey

Example DL-E 50/170-7.5/2-R1
DL-E In-line double pump with electronic control
50 Nominal diameter DN of the pipe connection
170 Nominal impeller diameter
7.5 Rated motor power P2 in kW
2 Number of poles
R1 Version without pressure sensor

Technical data

  • Permissible temperature range of -20 °C to +140 °C
  • Mains connection
    • 3~440 V ±10 %, 50/60 Hz
    • 3~400 V ±10 %, 50/60 Hz
    • 3~380 V -5 % +10 %, 50/60 Hz
  • Compliance with electromagnetic compatibility without additional measures:
    • Interference emission for residential environment according to EN 61800-3:2018
    • Interference immunity for industrial environments according to EN 61800-3:2018
  • Protection class IP55
  • Nominal diameter DN 40 to DN 200
  • Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C

Materials

  • Pump housing and lantern: EN-GJL-250
  • Impeller:
    • Standard version: EN-GJL-200
    • Special version: Bronze CuSn 10
  • Shaft: 1.4122
  • Mechanical seal: AQEGG; other mechanical seals on request

Construction

Single-stage, low-pressure double pump in in-line design with

  • Switchover valve
  • Mechanical seal
  • Flange connection
  • Lantern
  • Coupling
  • Drive with integrated electronic speed control

Scope of delivery

  • Pump
  • Installation and operating instructions

Options

  • Variant …-R1 without differential pressure sensor
  • ...-L1 variant with bronze impeller (at additional charge)

Accessories

  • 3 Mounting brackets with fixation material for installation on a base
  • Blind flanges for double pump housing
  • IR-Monitor, Wilo-IR-Stick
  • IF-Module PLR for connecting to PLR/interface converter
  • IF-Module LON for connection to the LONWORKS network
  • IF-Module BACnet
  • IF-Module Modbus
  • CAN IF-Module
  • VR-HVAC control system
  • Control system CCe-HVAC
  • Control system SCe-HVAC
  • Differential pressure sensor (DDG)

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System


Product Tags:

Heating water Wilo Recirculating Pump

      

Chilled Water Wilo Recirculating Pump

      

Wilo small water circulation pump

      
Best Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System wholesale

Small Twin Head Wilo Recirculating Pump For Heating Chilled Water And Cooling System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tianjin Shiny-Metals Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)